Meter read reason codes
Meter read reason codes identify the business reason that SAP is requesting the meter data. IEE MDUS uses these codes to determine which register reading to return for the requested day.
Read windows define the number of minutes forward and back that IEE MDUS searches when SAP requests a register read. Read windows are also known as the "lead and lag parameters" for the type of read.
Read category |
Default read window |
Supported reason codes |
---|---|---|
On-Demand Read |
N/A |
03 Final Meter Reading |
SapClosestReadDaysRange |
Lead: 1440 minutes Lag: 2880 minutes IEE returns the midnight read closest to 24 hours before the billing stop date. If there is no midnight read in the previous 24 hours, IEE returns the closest midnight read within 48 hours after the billing stop date. |
01 Periodic Meter Reading 02 Interim Meter Reading 09 Interim Meter Read Without Billing 10 Control Reading 13 Disconnect Meter Read 18 Reconnection Meter Read |
SapEarliestReadInDay |
Lead: 1439 minutes Lag: None IEE returns the read closest to 23 hours and 59 minutes before midnight on the specified day. |
06 Move In Meter Read 08 Technical Installation 11 Meter Read Аfter Program Adjustment 21 Billing Install 24 Replacement Upon Installation |
SapLatestReadInDay. |
Lead: None Lag: 1440 minutes IEE returns the read closest to 23:59 on the specified day. |
12 Technical Removal 16 Meter Read Before Program Adjustment 17 Reading For Change Of Installation Structure 22 Billing Removal 25 Replacement Upon Removal |
SapLatestReadOneDayBack. |
Lead: None Lag: 1440 minutes IEE returns the read closest to 23:59 on the day before the specified day. |
The integration module provides this category but does not map reason codes to it by default. |